6.3.5.1 Setting the pulse multiplier or divisor
To menu operating mode will be set if incoming water flow pulses are multiplied or divided.
At pulse multiplication causes every incoming pulse in "n" (setting factor) metering stroke.
At pulse division will be of the incoming pulses in "n" (setting factor) cause 1 metering stroke.
6.3.6
Indicators in "External pulse processing" operation mode
Display in operation
Fig. 6.2
Fig. 6.3
6.3.6.1 Selecting
The "Internal operation mode" submenu appears and offers the following selection:
- Multiplication
- Division
Select the desired indicator using the Up or Down key.
Press START/STOP key.
The setting is applied immediately and the pump returns to the main menu.
Press the key function "MENU/EXIT"
The display shows the current or recently set operation mode.
The new factor (n) can be selected in pulse operation setting mode.
417101637_Lub-O-Mat
Meaning
Pulse multiplication
(Example:
10 external pulses
become 20 strokes)
Pulse division
(Example:
10 external pulses
become 20 strokes)
- 40 -
Pos
Description
1
Pulse memory active
2
Number of pulses received
3
Set factor
Press key function "MENU/EXIT".
The main menu appears with the
"operation mode" menu item
highlighted.
Press START/STOP key.
The operation mode menu which
appears is divided into: internal,
pulse and current.
Select the "Internal" operation
mode using the Up or Down key.
Press START/STOP key.
Fig. 6.4
Rev. 03-07.12