Inputs and outputs

7
Inputs and outputs
7.1

Inputs

Apply the control signals between the particular input and reference potential
(GND). In the standard version, the trigger input can be directly activated with
a logic signal (HCMOS), although voltages up to 12 V are also possible. The
inputs of device socket 2 are suitable for the signals of a PLC. The reference
potential in both cases is GND of device socket 1. The table below shows the
allocation of logic states to the voltage values at the input. Levels between the
stated high and low levels produce undefined states!
Reference potential
High level
Low level
Input resistance
Function
Quiescent level
Triggering event
1)
Stable level at trigger input used. The other wire must be at low level or not connected.
2)
Debouncing is dependent on the function set (IMD command), but not on the input used (device
socket 1 or 2).
7.2

Outputs

The output driver of the switch outputs is a PLC compatible static switch (High-
Side driver). Power for switching must be supplied via external operating
voltage U
. All the voltages apply to GND at device socket 1.
B2
When an output is activated, a positive level is given on the corresponding out­
put line, voltage is dependent on U
output and the GND potential of the switching load supply:
16
Trigger input
GND
>4 V
<1 V
70 kΩ
External trigger
1
High or low level
Transition from high to low
level
. The connected consumer is between the
B2
A3916-2.0 HBM: public
Inputs IN1, IN2
GND
>10 V
<6 V
9 kΩ
TAR, Break, RUN functions
Low level
High level, debounced
2
FIT®5A