Electrical connection
Connection
1
2
3
4
5
6
7
8
1)
In extended version E, you must connect GND (pin 1) of device socket 1 to GND of the voltage
supply of the second device socket (inputs/outputs). See Section 7, Page 16.
2)
The standard version S does not have a diagnostic channel. Pin 4 is then the trigger input, pin 2
must not be connected.
Connection
1
2
3
4
5
6
7
8
1)
The signals apply to GND of socket 1. You must connect the GND wire of the voltage supply of
device socket 2 to pin 1 (GND) of device socket 1, as device socket 2 does not have a connection
for this. See Section 7, Page 16.
Suitable connection cables and the color code used can be found in the HBM
data sheet "Cables with a plug", B3643.
12
Device socket 1
RS‐485
1)
GND
Diag RbTb or not used
RA
Diag RaTa or trigger
RB
TB
TA
U
B1
Device socket 2 (extended version E)
-
IN2
OUT2
IN1
OUT4
OUT3
OUT1
1)
U
B2
A3916-2.0 HBM: public
CANopen/DeviceNet
GND
2)
Diag RbTb or not used
CAN‐High IN
2)
Diag RaTa or trigger
CAN‐Low IN
CAN‐Low OUT
CAN‐High OUT
U
B1
2)
2)
1)
FIT®5A