600 V overload protection
Measuring voltage: Approx. 1.0 V, measuring current approx. 0.7 mA
*Accuracy for measuring range ≤ 200 Ω was calculated after deducting lead
resistance from the REL function

Battery test

9
Range
Load resistance
1.5 V
Approx. 100 Ω
9 V
Approx. 900 kΩ
600 V overload protection
Fuses: µA/mA = 2x 0.5 5 A/240 V resettable, 1x F2 2.5 A/700 V ceramic
Diode test
1 0
Test voltage
Approx. 3.0 V/DC
Overload protection: 600 V; Test voltage: 2 mA.

Acoustic continuity test

1 1
Measurement range
200 Ω
≤10 Ω continuous tone; ≥100 Ω no tone
Overload protection: 600 V
Test voltage approx. 1 V
Test current <1.5 mA
Never exceed the maximum permitted input values. Never touch circuits
or circuit components if they may carry voltages greater than AC 30
Vr.m.s, 42.4 V peak or DC 60 V. This may cause a fatal electric shock!
86
Resolution
0.001 V
0.01 V
Resolution
0.001 V
Resolution
0.1 Ω
Accuracy
±(0.9% + 8)