Specified measuring range: 5–100% of the measuring range
Frequency range: 45–400 Hz; 600 V overload protection; Impedance: 10 MΩ
(mV: ≤100 MΩ)
The multimeter may display 5 counts if a measuring input is short-circuited.
After using the LoZ feature, leave the multimeter for 1 minute before using it
again.
TrueRMS peak for non-sinusoidal signals plus tolerance
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
CF >1.0 - 2.0
CF >2.0 - 2.5
CF >2.5 - 3.0
Direct current (A/DC)
6
Range
200.0 µA
2000 µA
20.00 mA
200.0 mA
2.000 A
10.00 A
600 V overload protection
Fuses: µA/mA = 2x 0.5 5 A/240 V resettable, 1x F2 2.5 A/700 V ceramic
10 A = High-performance FF10A/600V ceramic fuse
≤ 6 A = continuous measurement, >6A = max. 30 secs at intervals of 15 minutes
The multimeter may display 3 counts when a measuring input is open
7
84
+ 3%
+ 5%
+ 7%
Resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
0.001 A
0.01 A
Accuracy
±(0.9% + 5)