Dear Customer,
Thank you for choosing one of our products. Our name
stands for high-quality, thoroughly tested products for the
applications in the areas of heat, weight, blood pressure,
body temperature, pulse, gentle therapy, massage and air.
Please read these instructions for use carefully and keep
them for later use, be sure to make them accessible to
other users and observe the information they contain.
Best regards,
Your Beurer Team

1. Getting to know your instrument

The UPPER blood pressure monitor is used for non-
invasive measurement and monitoring of adults' arterial
blood pressure.
You can use it to measure your blood pressure quickly and
easily, storing the results and displaying the progression of
readings together with the average.
Keep these instructions carefully for further use and also let
other users have access to them.
2. Important information
Advice on use
Always measure your blood pressure at the same time of
day, in order to ensure that values are comparable.
Relax for approx. 5 minutes before each measurement.
enGlIsh
You should wait five minutes before measuring a second
time.
The readings that you take may only be used for informa-
tion purposes – they are not a substitute for a medical
examination! Discuss your results with the doctor. Never
use them to make medical decisions independently (e.g.
regarding medication and dosage thereof).
There may be incorrect measurements where there is
cardiocirculatory disease, as well as with very low blood
pressure, circulatory disorders, dysrhythmia and other
preexisting diseases.
Only use the instrument on persons whose upper arm
has the right circumference for the instrument.
You may only operate the blood pressure monitor with
batteries. Note that it is only possible to save data when
your blood pressure monitor is receiving power. As
soon as the batteries are dead, the date and time on
the blood pressure monitor are lost. Any measurement
results that have been stored are however retained.
The automatic switch-off function switches off the blood
pressure monitor in order to preserve the batteries, if no
button is pressed within one minute.
storage and Care
The blood pressure monitor is made up of precision
electronic components. Accuracy of readings and the
instrument's service life depend on careful handling.