Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1.3.1 Avoiding misuse

Cleaning brushes may be used only on the grinding machine GZ20C, GZ20CD and GZ25C, GZ25CD.
The distance between the supporting surface for grinding wheel may not be less than 2 mm. However,
the distance may be greater if the grinding process and the used material require this for security rea-
sons.
Grinding wheels must not be installed in places that are designed for cleaning brushes.
We would like to stress that any modifications to the construction, or technical or technological modifications
that have not been authorized by will also render the guarantee null and void.
WARNING!
Risk of injury caused by workpieces flying off
Make sure to have the gap between the grinding wheel and support surface as small as possible and read-
just the support surface immediately if the distance is too big.
If the readjustment of the support surface is no longer possible, the grinding wheel must be replaced.
INFORMATION
Grinding machines with frequency converter for regulating the speed are built according to the standard DIN
EN -3 class C2.
WARNING!
This machines are not intended for use in residential facilities where the power is supplied via a
public low voltage supply system. In these areas, it may be difficult to guarantee electromagnetic
compatibility due to conducted and emitted interference.
Overview of the EMC categories:
Categorie C1
required limit values Class B Group 1 according to EN 55011
Categorie C2
Required limit values class A Group 1 according to EN 55011, Installation by EMC expertsand warning:
"This is a product of category C2 according to EN 61800-3. This product may cause radio interference in
a residential area. In this case, it may be necessary for the operator to take appropriate action."
Categorie C3
Required limit values class A group 2 according to EN 55011, whereby these limit values are below those
of class A group 1, plus warning: "This type is not suitable for connection to a public low-voltage network
supplying residential buildings. When connecting to a public low voltage network, radio frequency inter-
ference is expected."
Speed regulated
grinding machines
Categorie
Environment
Voltage / Current
EMC knowledge
EN
GZ grinding machines
24
C1
C2
Residential area
Business area
Industrial area
< 1000 V
no requirement
Installation and commissioning by an EMC expert
Translation of original instruction
C3
C4
Industrial area
> 1000 V
Version 1.0.2 - 2021-5-5

Werbung

Inhaltsverzeichnis
loading