Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Environment And Recycling - clage DEX Next S Gebrauchs- Und Montageanleitung

E-komfortdurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

2. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
Chosen capacity / current
Electrical connection
Min. required cable size
1)
Hot water (l/min)
2)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required spec. water resistance
Spec. electrical conductivity
Inlet temperature
Switch on – max. flow rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
Transmission and receiving frequency
range Bluetooth
Transmission power Bluetooth
Radiation
Transmission range
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013.
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Electronically controlled depending on the desired temperature and cold water temperature

3. Environment and recycling

This product was manufactured climate neutrally according to Scope 1 + 2. We recommend the purchase of 100% green electricity
to make the operation climate neutral as well.
Your product was manufactured from high-quality, reusable materials and components. Please respect in case of discarding that
electrical devices should be disposed of separately from household waste at the end of their service life. Therefore, please take this
device to a municipal collection point that return used electronic devices to the recycling system. Disposing it correctly will support
environmental protection and will prevent any potential negative effects on human beings and the environment that could arise
from inappropriate handling of these devices at the end of their service life. Please contact your local authority for further details of
your nearest designated collection point or recycling site.
Business customers: If you wish to discard equipment, please contact your dealer or supplier for further information.
18 kW / 26 A
3~ / PE 380..415 V AC
4.0 mm
2
9.2
6.8
0.08 bar at 1.5 l/min
in electrical connection from above.
2
43
DEX Next S
A *
)
18 kW..27 kW (26 A..39 A)
21 kW / 30 A
24 kW / 35 A
4.0 mm
6.0 mm
2
10.7
12.3
7.9
9.0
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90 mS/m
≤ 70 °C
1.5 l/min – automatic
3)
1.3 bar at 9.0 l/min
20 – 60 °C [70 °C]
G ½ inch
4.5 kg
2.4 – 2.4385 GHz
≤ 8 mW
undirected
10 meter incl. barrier
I
IP25
CLAGE
27 kW / 39 A
3~ / PE 400 V AC
6.0 mm
2
2
13.8
10.2
®
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis