7. Electrical connection
EN
A

Electrical connection from below

Note: If necessary, the connecting terminal can be displaced to the upper part of the
appliance. If you want to do so, please follow the instructions in the next chapter.
Check that the power supply is switched off prior to electrical connection!
1. Dismantle approximately 6 cm off the connecting cable above the wall outlet. With
the smaller opening ahead, slide the water splash protection sleeve over the con-
necting cable so that the sleeve is flush with the wall. This prevents any leaking
water from coming into contact with the electrical leads. It must not become dam-
aged! The protection sleeve must be used!
2. Open the control panel holder rightwards.
3. Strip the cables and plug them in the connecting terminals according to the wiring
diagram. The appliance must be earthed.
4. Pull the protective sleeve over the connecting cables until the sleeve fits perfectly
in the recess of the intermediate panel. Adjust the water splash protection sleeve as
illustrated and fix it with the sleeve fixing (A). Reinsert the control panel holder and
lock it on.
5. Place the hood on the appliance and screw in the fastening screw. After that you
can slide on the faceplate from the bottom up to the stop.

Electrical connection from above

Check that the power supply is switched off prior to electrical connection!
1. Open the prepared breaking point (S) in the upper part of the appliance by press-
ing with a blunt implement (e.g. srewdriver).For surface-mounted connection cable
additional open the breakout at the right side of the bottom part.
S
2. Slit the grommet to match the cable size. The opening in the grommet should be
slightly smaller than the cross-section of the cable in order to ensure optimum pro-
tection against water. Fit the grommet into the opening. The protection grommet
must be used!
3. Strip the connection cable so that the sheath extends through the grommet into
the appliance. Hold the prepared appliance in one hand and route the cable into the
grommet with the other hand.
4. Place the appliance on the wall bracket so that the threaded rod of the wall bracket
fits in the corresponding hole of the appliance and fix the appliance.
5. Screw the connecting terminal of the adapter cable to the upper connection point.
Route the adapter cable past the power section on the left and attach the two
brackets to the heating block.
6. Open the control holder panel. Connect the other end of the adapter cable to the
lower connecting terminal according to the wiring diagram. Observe outer conduc-
tor assignment!
7. Strip the individual wires of the connection cable and plug them in the upper con-
necting terminal according to the wiring diagram. The appliance must be earthed.
8. Fold back control panel holder and lock it in place.
9. Place the hood on the appliance and screw in the fastening screw.
Note: To ensure IP25 protection class, please don´t remove the bottom water splash
protection sleeve.