Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instruction; Overview; Technical Specifications; Dimensions - clage CEX 9-U Gebrauchs- Und Montageanleitung

E-kompaktdurchlauferhitzer
Vorschau ausblenden Andere Handbücher für CEX 9-U:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
CEX 9-U / CEX 9

Installation instruction

1. Overview

See figure C1
EN
Pos.
Function
1
Filter
2
Hood
3
Inlet pipe
4
Control panel
5
Electronics
6
Non-return valve
7
Flow sensor
8
Connecting terminal

2. Technical specifications

Model
Energy efficiency class
Rated capacity (Rated current)
Chosen capacity (Chosen current)
Electrical connection
Min. required cable size
1)
Hot water (l/min)max. at ∆t = 25 K
Rated volume
Rated pressure
Connecting type
Heating system
Required spec. water
resistance @ 15 °C
Spec. electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature choice
Water connection
Weight (when filled w. water)
VDE class of protection
Type of protection
Type of safety
*) The declaration complies with the EU regulation No 812/2013
1) Maximum cable cross section: 10 mm
2) Flow rate limited to achieve optimum temperature rise
3) Without flow regulator

3. Dimensions

Dimensions in mm (fig. D1)
6.6 kW (28.7 A)
3× 4 mm
2
3.8
2
Pos.
Function
9
Grommet
10
Screws and dowels
11
Cold and hot water connection
12
Safety thermal cut-out STB
13
Temperature sensor set
14
Heating element with SDB
15
Bottom part
CEX 9-U
A *
)
6.0 / 9.6 kW (27.3 / 40 A)
8.8 kW (38.3 A)
1 / N / PE 220..240 V AC
3× 6 mm
2
5.0
0.3 l
1.0 MPa (10 bar)
pressure resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90.9 mS/m
≤ 60 °C
2.0 – 5.0 l/min
0,2 bar at 2,5 l/min
1,3 bar at 9,0 l/min
20 °C – 55 °C
G ½"
2.7 kg
I
IP24
13
CEX 9
6.6 kW (28.7 A)
8.8 kW (38.3 A)
3× 4 mm
3× 6 mm
2
3.8
5.0
®
2)
3)
IP25
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cex 9

Inhaltsverzeichnis