CEX 9-U ELECTRONIC MPS ®

2. Technical specifications

Model
Energy efficiency class
Rated capacity (Rated current)
EN
Chosen capacity (Chosen current)
Electrical connection
Min. required cable size
Hot water (l/min)
max. at ∆t = 25 K
Rated volume
Rated pressure
Connecting type
Heating system
Required spec. water
resistance @ 15 °C
Spec. electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature choice
Water connection
Weight (when filled w. water)
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013
1) Flow rate limited to achieve optimum temperature rise
2) Without flow regulator
3) The cable size may not exceed 10 mm²

3. Dimensions

3)
CEX-U ELECTRONIC MPS ®
A *
6.0 / 9.6 kW (27.3 / 40 A)
6.6 kW (28.7 A)
1/N/PE 220..240 V AC
3× 4 mm
2
3.8
0.3 l
1.0 MPa (10 bar)
pressure resistant / pressureless
Bare wire heating system IES ®
≥ 1100 Ωcm
≤ 90.9 mS/m
≤ 60 °C
2.0 – 5.0 l/min
0.2 bar at 2.5 l/min
20 °C – 55 °C
G ½"
2.7 kg
I
Dimensions in mm
14
)
8.8 kW (38.3 A)
3× 6 mm
2
5.0
1)
1.3 bar at 9.0 l/min
2)
IP24