Verfügbare Sprachen

Verfügbare Sprachen

BAE SA-OH-059-YI- ----
Photoelectric Sensors
8
Menu structure (continued)
8.2.2

Switchpoint Mode

Single Point Mode
In Single Point Mode, only one switching point (setpoint) is
defined.
Switching behavior:
Measurement value ≥ switching point: output active
Measurement value ≤ switching point minus a defined
hysteresis: output inactive
Low
SP1-Hys
Fig. 8-9:
Switchpoint Mode
Single Point Mode
Two-Point Mode
In Two-Point Mode, two switching points (setpoints) are
defined.
Switching behavior:
Measurement value ≥ switching point 1: output active
Measurement value ≤ switching point 2: output inactive
Low
SP2
Fig. 8-10:
Switchpoint Mode Two Point Mode
Window Mode
In Window Mode, two switching points (setpoints) are
defined.
Switching behavior:
If the output is inactive and the measurement value is
greater than or equal to switching point 2 + 50% of the
set hysteresis and the measurement value is less than
or equal to switching point 1 – 50% of the set hystere-
sis, the output switches to active.
If the output is active and the measurement value is
less than or equal to switching point 2 – 50% of the set
hysteresis or the measurement value is greater than or
equal to switching point 1 + 50% of the set hysteresis,
the output switches to inactive.
16
english
High
SP1
Measurement value
High
SP1
Measurement value
Hyst.
Low
SP2
Fig. 8-11:
Switchpoint Mode Window Mode
Dynamic Mode
In this mode a dynamic signal evaluation is performed,
allowing slow changes of the signal value, e.g. due to dust
accumulation on the optics or temperature drift, to be
compensated for. The switching threshold is below or
above the average signal value. Dynamic behavior means
that switching only takes place in the event of rapid signal
changes and that the output becomes inactive again if the
signal remains constant thereafter.
Threshold Hi
Threshold Lo
Signal
Out
Fig. 8-12:
Switchpoint Mode Dynamic Mode Negative
Threshold Hi
Threshold Lo
Signal
Out
Fig. 8-13
Switchpoint Mode Dynamic Mode Positive
Hyst.
High
SP1
Measurement value
t
t