Every procedure described in this instruction manual indicates the possible risks. Always follow the
instructions in the instruction manual to avoid damage or injury.
Follow the warnings given in this instruction manual concerning installation.
l
Follow the instructions for adjustment, cleaning and maintenance given in this instruction manual.
l
2.3.2 Preamble
The packaged unit has been designed and built to function, be adjusted and subjected to maintenance
without these operations exposing the personnel in charge to risks if carried out according to the
instructions given in this instruction manual. The adopted measures minimize the risk of accidents
throughout the life cycle of the packaged unit, both in the context of the intended use and of reasonably
foreseeable misuse.
2.3.3 Mechanical residual risks
Risk
Bruising and
During installation, cleaning,
superficial abrasion
maintenance and dismantling.
Crushing
During transportation, lifting,
installation and dismantling.
Falling from above
During installation,
maintenance at a height and
dismantling.
Impact
During installation, cleaning
and maintenance.
High pressure fluid
During maintenance and
ejection
dismantling.
Contact with moving
During maintenance.
and sharp parts
2.3.4 Electrical residual risks
Risk
Electrocution
During installation, connection,
maintenance and dismantling.
2.3.5 Thermal residual risks
Risk
Low temperatures
During maintenance in the
coldroom.
Burns
During and immediately after
use.
Instruction manual
v. 00 | 9600-0033
Rev.
BEST W R290
When it occurs
Wear the personal protective equipment.
Always use adequate means and accessories.
Wear the personal protective equipment.
Maintenance on pressurized circuits must only be
performed by the mechanical maintenance engineer.
When it occurs
When it occurs
Wear the personal protective equipment.
© 2020 RIVACOLD srl
|
How to avoid it
Always use lifting equipment and accessories of
l
adequate capacity for the load to be lifted.
Prevent UNAUTHORIZED people from accessing
l
the area near the packaged unit.
Follow the warnings given in this instruction
l
manual concerning lifting.
Check that the wall where the packaged unit is
l
installed is suitable for supporting the packaged
unit.
Wear the personal protective equipment.
l
Isolate the packaged unit from the power supply.
l
How to avoid it
The electrical connection and disconnection must
l
only be carried out by the electrical maintenance
engineer.
Wear the personal protective equipment.
l
How to avoid it
Wear the personal protective equipment.
l
Follow the instructions for adjustment, cleaning
l
and maintenance given in this instruction manual.
Take work breaks to prevent long exposure to
l
excessively low temperatures.
EN
2. Safety
85