Herunterladen Diese Seite drucken

System Resources Operation; Temperature; Temperature Upper-Limit; Temperature Lower-Limit - Belden HIRSCHMANN EAGLE40-07 Referenzhandbuch

Grafische benutzeroberfläche; anwender-handbuch konfiguration
Vorschau ausblenden Andere Handbücher für HIRSCHMANN EAGLE40-07:

Werbung

4 3 .1 .6
syst e m re sourc e s ope ra t ion
Enable or disable the measurement operation.
Mode: Global Config Mode
Privilege Level: Administrator
Format: system resources operation
no syst e m re sourc e s ope ra t ion
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no system resources operation
4 3 .2
t e m pe rat ure
Configure the upper and lower temperature limits of the device. The device allows you to set the threshold as an
integer from -99 through 99. You configure the temperatures in degrees Celsius.
4 3 .2 .1
t e m pe ra t ure uppe r-lim it
Configure the upper temperature limit.
Mode: Global Config Mode
Privilege Level: Administrator
Format: temperature upper-limit <P-1>
Parameter Value
-99..99
P-1
4 3 .2 .2
t e m pe ra t ure low e r-lim it
Configure the lower temperature limit.
Mode: Global Config Mode
Privilege Level: Administrator
Format: system location <P-1>
Parameter Value
string
P-1
4 3 .3

show

Display device options and settings.
4 3 .3 .1
show e ve nt log
Display the event log notice and warning entries with time stamp.
Mode: Command is in all modes available.
Privilege Level: Guest
Format: show eventlog
4 3 .3 .2
show syst e m info
Display the system related information.
Mode: Command is in all modes available.
Privilege Level: Guest
Format: show system info
4 3 .3 .3
show syst e m pre -login-ba nne r
Display the pre-login banner status and text.
Mode: Command is in all modes available.
Privilege Level: Guest
Format: show system pre-login-banner
148
Meaning
Upper temperature threshold ([C], default 70).
Meaning
Enter a user-defined text, max. 255 characters.
RM CLI EAGLE40-07
Release 04.1.01 05/2021

Werbung