1 7 I nt e rfa c e

1 7 .1
shut dow n
1 7 .1 .1
shut dow n
Enable or disable the interface.
Mode: Interface Range Mode
Privilege Level: Operator
Format: shutdown
no shut dow n
Disable the option
Mode: Interface Range Mode
Privilege Level: Operator
Format: no shutdown
1 7 .2
a ut o-ne got iat e
1 7 .2 .1
a ut o-ne got ia t e
Enable or disable automatic negotiation on the interface. The cable crossing settings have no effect if auto-
negotiation is enabled. In this case cable crossing is always set to auto. Cable crossing is set to the value chosen
by the user if auto-negotiation is disabled.
Mode: Interface Range Mode
Privilege Level: Operator
Format: auto-negotiate
no a ut o-ne got ia t e
Disable the option
Mode: Interface Range Mode
Privilege Level: Operator
Format: no auto-negotiate
1 7 .3
a ut o-pow e r-dow n
1 7 .3 .1
a ut o-pow e r-dow n
Set the auto-power-down mode on the interface.
Mode: Interface Range Mode
Privilege Level: Operator
Format: auto-power-down <P-1>
Parameter Value
auto-power-save
P-1
no-power-save
1 7 .4
c a ble -c rossing
1 7 .4 .1
c a ble -c rossing
Cable crossing settings on the interface. The cable crossing settings have no effect if auto-negotiation is enabled.
In this case cable crossing is always set to auto. Cable crossing is set to the value chosen by the user if auto-
negotiation is disabled.
Mode: Interface Range Mode
Privilege Level: Operator
Format: cable-crossing <P-1>
68
Meaning
The port goes in a low power mode.
The port does not use the automatic power save mode.
RM CLI EAGLE40-07