Parameter Value
readonly
P-3
readwrite
programming
all
advanced
1..255
P-4
1|0-65535
2|0-65535
3|0-65535
4|0-65535
5|0-65535
6|0-65535
7
8
11
12
13
14
15|0-65535
16|0-65535
17
20
21
22|0-65535
23|0-65535|0-65535 Function code read/write multiple registers, read address range 0 - 65535,
24|0-65535
40
42
43
48
66
67
90
100
125
126
0..255
P-5
none
yes
P-6
no
yes
P-7
no
yes
P-8
no
1 1 .1 .4
dpi m odbus c opyprofile
Copies a profile to another DPI MODBUS profile.
Mode: Global Config Mode
Privilege Level: Operator
Format: dpi modbus copyprofile <P-1> <P-2>
Parameter Value
1..32
P-1
1..32
P-2
1 1 .1 .5
dpi m odbus de lprofile
Deletes a profile from the DPI MODBUS profile table. You cannot delete an active profile or if an enforcer
mappings to it.
Mode: Global Config Mode
Privilege Level: Operator
Format: dpi modbus delprofile <P-1>
Parameter Value
1..32
P-1
48
Meaning
Read only function codes for function code list
Read write function codes for function code list
Programming function codes for function code list
All possible function codes for function code list (allow any function code)
Keeps the function code list from the previous selection and makes it editable
by the user
Function codes 1 - 255
Function code read coils, coil address range 0 - 65535
Function code read discrete inputs, input address range 0 - 65535
Function code read holding registers, register address range 0 - 65535
Function code read input registers, register address range 0 - 65535
Function code write single coil, coil address range 0 - 65535
Function code write single register, register address range 0 - 65535
Function code read exception status
Function code diagnostic
Function code get com event counter
Function code get comm event log
Function code program (584/984)
Function code poll (584/984)
Function code write multiple coils, coil address range 0 - 65535
Function code write multiple registers, register address range 0 - 65535
Function code report slave id
Function code read file record
Function code write file record
Function code mask write register, register address range 0 - 65535
write address range 0 - 65535
Function code read fifo queue, pointer address range 0 - 65535
Function code program (concept)
Function code concept symbol table
Function code encapsulated interface transport
Function code advantech co. ltd. - management functions
Function code scan data inc. - expanded read holding registers
Function code scan data inc. - expanded write holding registers
Function code unity programming/ofs
Function code scattered register read
Function code schneider electric - firmware replacement
Function code schneider electric - program
Unit identifier 0 - 255
No unit identifier 'none'
True
False
True
False
True
False
Meaning
Profile source index 1 - 32
Profile destination index 1 - 32
Meaning
Profile index 1 - 32
RM CLI EAGLE40-07
Release 04.1.01 05/2021