Code
Problem
E024
The excess current protec-
tion of the battery has
been activated
E025
The battery does not rec-
ognise the drive unit.
E030
The installed shifting unit
does not correspond with
the unit set in the system
configuration.
E033
The current firmware is not
supported by this system.
E034
Deviation detected in the
(E013)
firmware of the drive unit.
E035
Configuration error.
Situation
No system functions will
start.
No system functions will
start.
No assistance will be given
while cycling.
No assistance will be given
while cycling.
No assistance will be given
while cycling.
No assistance will be given
while cycling.
Gazelle Easyflow HMS Manual | 61
Remedy
Ask your Gazelle service specialist to carry out the following:
Connect an original SHIMANO battery. And check the
power cable for any deviations.
If the fault does not disappear, contact your Gazelle service
specialist.
Ask your Gazelle service specialist to carry out the following:
Connect an original SHIMANO battery. And check the
power cable for any deviations.
If the fault does not disappear, then contact your Gazelle ser-
vice specialist.
Ask your Gazelle service specialist to carry out the following:
Replace with a shifting unit that has been configured in
the system.
Or check the current system status with E-TUBE PRO-
JECT.
Ask your Gazelle service specialist to carry out the following:
Connect to E-TUBE PROJECT to update the firmware on
all units of the electrically assisted bike to the latest ver-
sion.
Contact your Gazelle service specialist or a distributor. The
firmware must be restored.
Ask your Gazelle service specialist to carry out the following:
Connect to E-TUBE PROJECT to check the configuration.