Herunterladen Inhalt Inhalt Diese Seite drucken

Airwell WELLEA MONOBLOC DF A R32 Installationsanleitung Seite 53

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 155
NOTE
ROOM THERMOSTAT = NON, no room thermo-
stat.
ROOM THERMOSTAT = MODE SET, the wiring of
room thermostat should follow method A.
ROOM THERMOSTAT=ONE ZONE, the wiring of
room thermostat should follow method B.
ROOM THERMOSTAT=DOUBLE ZONE, the wiring
of room thermostat should follow method C (refer to
9.7.6 "Connection for other components/For room
thermostat")
10.7.7 Other HEATING SOURCE
The OTHER HEATING SOURCE is used to set the
parameters of the backup heater, additional heating
sources and solar energy kit.
Go to MENU> FOR SERVICEMAN> 7.OTHER HEATING
SOURCE, Press OK. The following page will be dispayed:
7 OTHER HEATING SOURCE
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
ADJUST
7 OTHER HEATING SOURCE
7.6 T4_AHS_ON
7.7 IBH LOCATE
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
ADJUST
10.7.8 HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING is used to set the outlet
water temperature to prevent freezing when away for
holiday.
Go to MENU> FOR S ERVICEMAN> 8.HOLIDAY AWAY
SETTING. Press OK. The following page will be
displayed:
8 HOLIDAY AWAY SETTING
8.1 T1S_H.A._H
8.2 T5S_H.A._DHW
ADJUST
10.7.9 SERVICE CALL SETTING
The installers can set the phone number of the local
dealer in SERVICE CALL SETTING. If the unit doesn't
work properly, call this number for help.
Go to MENU> FOR SERVICEMAN>SERVICE CALL.
Press OK. The following page will be displayed:
1/2
5°C
30MIN
-5°C
5°C
30MIN
2/2
-5°C
PIPE LOOP
0.0kW
0.0kW
2.0kW
20°C
20°C
49
9 SERVICE CALL SETTING
PHONE NO. 0000000000000
MOBILE NO. 0000000000000
OK
CONFIRM
ADJUST
Press ▼ ▲ to scroll and set the phone number. The
maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input ■,
as shown below:
9 SERVICE CALL
PHONE NO. 33512345678
MOBILE NO. 8613929145152
OK
CONFIRM
ADJUST
The number displayed on the user interface is the phone
number of your local dealer.
10.7.10 RESTORE FACTORY SETTINGS
The RESTORE FACTORY SETTING is used to restore
all the parameters set in the user interface to the factory
setting.
Go to MENU> FOR SERVICEMAN> 10.RESTORE
FACTORY SETTINGS. Press OK. The following page will
be displayed:
10 RESTORE FACTORY SETTINGS
All the settings will come back to
factory default.
Do you want to restore factory
settings?
NO
OK
CONFIRM
Press
to scroll the cursor to YES and press OK. The
following page will be displayed:
10 RESTORE FACTORY SETTINGS
Please wait...
5%
After a few seconds, all the parameters set in the user
interface will be restored to factory settings.
10.7.11 TEST RUN
TEST RUN is used to check correct operation of the
valves, air purge, circulation pump operation, cooling,
heating and domestic water heating.
YES

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis