10.7.1 DHW MODE SETTING
DHW = domestic hot water
Go to MENU> FOR SERVICEMAN> 1.DHW MODE
SETTING. Press OK. The following pages will be
displayed:
1
DHW MODE SETTING
1.1 DHW MODE
1.2 DISINFECT
1.3 DHW PRIORITY
1.4 DHW PUMP
1.5 DHW PRIORITY TIME SET
ADJUST
1 DHW MODE SETTING
1.6 dT5_ON
1.7 dT1S5
1.8 T4DHWMAX
1.9 T4DHWMIN
1.10 t_INTERVAL_DHW
ADJUST
1 DHW MODE SETTING
1.11 dT5_TBH_OFF
1.12 T4_TBH_ON
1.13 t_TBH_DELAY
1.14 T5S_DI
1.15 t_DI HIGHTEMP.
ADJUST
1 DHW MODE SETTING
1.16 t_DI_MAX
1.17 t_DHWHP_RESTRICT
1.18 t_DHWHP_MAX
1.19 DHWPUMP TIME RUN
1.20 PUMP RUNNING TIME
ADJUST
1 DHW MODE SETTING
1.21 DHW PUMP DI RUN
ADJUST
10.7.2 COOL MODE SETTING
Go to MENU> FOR SERVICEMAN> 2.COOL MODE
SETTING. Press OK.
The following pages will be displayed:
2 COOL MODE SETTING
2.1 COOL MODE
2.2 t_T4_FRESH_C
2.3 T4CMAX
2.4 T4CMIN
2.5 dT1SC
ADJUST
2 COOL MODE SETTING
2.6 dTSC
2.7 t_INTERVAL_C
2.8 T1SetC1
2.9 T1SetC2
2.10 T4C1
ADJUST
1/5
YES
YES
YES
YES
NON
2/5
5
°C
10°C
43°C
-10°C
5 MIN
3/5
5
°C
5 °C
30 MIN
65°C
15MIN
4/5
210
MIN
30 MIN
120 MIN
YES
5 MIN
5/5
NON
10.7.5 TEMP. TYPE SETTING
The TEMP. TYPE SETTING is used for selecting whether
the water flow temperature or room temperature is used
to control the ON/OFF of the heat pump.
When ROOM TEMP. is enabled, the target water flow
temperature will be calculated from climate-related curves
1/3
(refer to 10.1 "Climate related curves" ).
YES
How to enter the TEMP. TYPE SETTING
2.0HRS
43°C
Go to MENU> FOR SERVICEMAN> 5.TEMP. TYPE
SETTING. Press OK. The following page will be
20°C
displayed:
5°C
2/3
2°C
5MIN
10°C
16°C
35°C
47
2 COOL MODE SETTING
2.11 T4C2
2.12 ZONE1 C-EMISSION
2.13 ZONE2 C-EMISSION
ADJUST
10.7.3 HEAT MODE SETTING
Go to MENU>FOR SERVICEMAN> 3.HEAT MODE
SETTING. Press OK. The following pages will be
displayed:
3 HEAT MODE SETTING
3.1 HEAT MODE
3.2 t_T4_FRESH_H
3.3 T4HMAX
3.4 T4HMIN
3.5 dT1SH
ADJUST
3 HEAT MODE SETTING
3.6 dTSH
3.7 t_INTERVAL_H
3.8 T1SetH1
3.9 T1SetH2
3.10 T4H1
ADJUST
3 HEAT MODE SETTING
3.11 T4H2
3.12 ZONE1 H-EMISSION
3.13 ZONE2 H-EMISSION
3.14 t_DELAY_PUMP
ADJUST
10.7.4 AUTO MODE SETTING
Go to MENU> FOR SERVICEMAN> 4.AUTO MODE
SETTING. Press OK, the following page will be displayed.
4 AUTO. MODE SETTING
4.1 T4AUTOCMIN
4.2 T4AUTOHMAX
ADJUST
5 TEMP. TYPE SETTING
5.1 WATER FLOW TEMP.
5.2 ROOM TEMP.
5.3 DOUBLE ZONE
ADJUST
3/3
25°C
FCU
FLH
1/3
YES
2.0HRS
16°C
-15°C
5°C
2/3
2°C
5MIN
35°C
28°C
-5°C
3/3
7°C
RAD.
FLH
2MIN
25°C
17°C
YES
NON
NON