S6.11
MINIMUM RPM
FOR PUMP
S6.12 MAXIMUM
SPEED TIME AT
PUMP START
S6.13 MIN. PW-
M/0–10V OF
THE PUMP
S6.14 MAX. PW-
M/0–10V OF
THE PUMP
S6.15 SWITCH-OFF
PWM/0–10V
OF THE PUMP
S6.16 LOCATION OF
COLD SENSOR
FOR DIFF.
THERMOSTAT
SERVICE SETTINGS FOR ALTERNATIVE ENERGY
SOURCES
Para-
Parameter name
meter
HEAT PUMP –
S7.1
OPERATION
MODE
Service setting manual
SERVICE PARAMETERS
Parameter description
Minimum RPM stage for modulation
of circulation pump.
1- 40 % RPM
2- 55 % RPM
3- 70 % RPM
When the differential condition is
fulfilled, the circulation pump runs at
max. RPM for a setted time.
Afterwards the pump is running with
RPM modulation (if enabled with
parameter S6.10=1).
Sets the minimum pump speed level.
The setting only applies for the con-
trol of the energy-saving circulation
pump speed.
Set up the maximum pump speed
level. The setting only applies for
the control of the energy-saving
circulation pump speed.
Set up the maximum pump speed
level. The setting only applies for the
control of the energy-saving
circulation pump speed.
Cold sensor (T8) place of mount, if
it is being used for differential ther-
mostat. In exact we define storage
device which is being warmed with
solar collectors or solid fuel boiler.
Parameter description
Configures whether the
heat pump control should be
constantly switched on or
weather-compensated.
EN
Setting range
Default
setting
1- 40 %
1
2- 55 %
3- 70 %
5 ÷ 300 s
20
20 ÷ 50 %
20
60 ÷ 100 %
100
0 ÷ 10 °C
0
1- D. H. W.
1
TANK
2- HEAT AC-
CUMULATOR
Setting range
Default
setting
1 – PERMA-
2
NENT
ACTIVATION
2 – WEATH-
ER-COMPEN-
SATED
61