SETTINGS FOR DOMESTIC HOT WATER
Para-
Parameter name
meter
P4.1
D. H. W.
TEMPERATURE
IN OFF PERIOD
P4.2 PRIORITY OF D.
H. W. WARMING
TO CIRCUIT 1
P4.3 PRIORITY OF D.
H. W. WARMING
TO CIRCUIT 2
P4.7 TIME
PROGRAM
FOR D. H. W.
CIRCULATION
P4.8 RUNNING TIME
FOR D. H. W.
CIRCULATION
PUMP
P4.9 STAND-BY TIME
FOR D. H. W.
CIRCULATION
PUMP
40
USER PARAMETERS
Parameter description
Setting of d. h. w. temperature in OFF
program timer interval.
Setting if d. h. w. heating has priority to
room heating in circuit 1.
Setting if d. h. w. heating has priority to
room heating in circuit 2.
Selection of d. h. w. warming time
program which will be used for d. h. w.
circulation.
Setting 1 is first time program for
domestic hot water warming.
Setting 2 is second time program
for domestic hot eater warming.
Setting 3 is selected time program for
domestic hot water warming.
Setting of running time for d. h. w.
circulation pump. Pump running
period is always followed by the pump
stand-by period.
Setting of stand-by time for d. h. w.
circulation pump. Pump stand-by
period is always followed by the pump
running period.
Setting range
Default
setting
4 ÷ 70 °C
4
0- NO
0
1- YES
0- NO
0
1- YES
1- PROG. 1
3
2- PROG. 2
3- SELECT.
PROG.
0 ÷ 600 sec
300
0 ÷ 60 min
10