Malfunction
Spray gun does not
shut air off.
Corrosion on air
cap thread, material
passages (cup con-
nection) or spray gun
body.
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at flu-
id tip ("fluid tip cone").

12. Disposal

Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!

13. After Sales Service

For accessories, spare parts and technical support, contact your SATA
dealer.
Cause
Air piston seat
clogged.
Air piston worn.
Cleaning solution (wa-
tery) remains in the
gun for too long.
Unsuitable cleaning
solutions used.
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective Action
Clean air piston seat.
Heed cleaning instruc-
tions (see chapter 10).
Replace air piston and
air piston packing (see
chapter 9.4).
Have gun body re-
placed. Heed cleaning
instructions (see chap-
ter 10).
Replace paint needle
seal (see chapter 9.3).
Replace nozzle set (see
chapter 9.1).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 10).
Clean fluid tip and paint 
needle. Heed cleaning
instructions (see chap-
ter 10).
Replace nozzle set (see
chapter 9.1).
EN