Herunterladen Inhalt Inhalt Diese Seite drucken

SATA SATAjet 1000 H RP Betriebsanleitung Seite 138

Vorschau ausblenden Andere Handbücher für SATAjet 1000 H RP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Operating Instructions SATAjet 1000 K (RP / HVLP) / H (RP)
EN
■ Insert air distribution ring. The pin [8-3] of the air distribution ring must
be aligned accordingly.
■ Press the air distribution ring in evenly.
■ Mount nozzle set (see chapter 9.1).
After installation, adjust the material flow according to chapter 8.2.
9.3. Replace paint needle seal
This must be replaced when material leaks from the self-adjusting paint
needle packing.
Dismantle paint needle seal
■ Loosen counter nut [1-3].
■ Screw adjusting screw [1-2] with counter nut out of the gun body.
■ Remove spring and paint needle [9-1].
■ Remove the trigger guard [9-2].
■ Screw the paint needle seal [9-3] out of the gun body.
Mount paint needle seal
■ Screw the paint needle seal [9-3] into the gun body.
■ Mount the trigger guard [9-2].
■ Insert spring and paint needle [9-1].
■ Screw adjusting screw [1-2] with counter nut [1-3] into the gun body.
After installation, adjust the material flow according to chapter 8.2.
9.4. Replace air piston, air piston spring and air
micrometer
Risk of injuries from air micrometer coming loose.
When the locking screw is not screwed tight, the air micrometer can
shoot uncontrolled out of the spray gun.
→ Check that the locking screw of the air micrometer fits firmly and 
tighten if necessary.
Replacement is necessary if
air escapes at the air cap or air micrometer without actuating the trigger
guard.
Dismantle air piston, air piston spring and air micrometer
■ Screw the locking screw [10-1] out of the gun body.
138
Warning!

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Satajet 1000 k rpSatajet 1000 k hvlp

Inhaltsverzeichnis