Operating Instructions SATAjet 1000 K (RP / HVLP) / H (RP)
is possible with the adjusting screw as shown in Figs. [4-1], [4-2], [4-3]
and [4-4].
■ Loosen counter nut [1-3].
■ Pull trigger guard [1-16] right back.
■ Adjust material flow at the adjusting screw [1-2].
■ Tighten counter nut by hand.
For SATAjet 1000 K
■ Pull trigger guard [6-2] right back and adjust material supply pressure.
Adjust spray fan pattern
Fully variable adjustment of the spray fan pattern is possible using the
round/flat fan control [1-1] to achieve a round fan.
■ Adjust the spray fan pattern by regulating the round and flat fan control 
[1-1].
■ Turn to the right [5-2] – for a round fan
■ Turn to the left [5-1] – for a flat fan
Start spraying process
■ Observe correct spray distance (see chapter 2).
■ Pull trigger guard right back [6-2] and hold spray gun at 90° to the
surface being sprayed [6-1].
■ Ensure there is sufficient spraying air feed and material supply.
■ Pull trigger guard [1-16] back and start spraying process. Adjust mate-
rial flow and spray fan pattern if necessary.
End the spraying process
■ Bring the trigger guard [1-16] to the starting position.
■ At the end of the spraying process, interrupt the spraying air and empty
the suction cup [1-10]. Comply with the instructions for care and stor-
age (see chapter 10).