The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identification and
correction of any anomalies and malfunctions
which might occur during use.
Faults
The heating elements do
not come on.
Overheating indicator light
on.
GB
3320120_ut_GB
3320120_ut_GB
FAULT
TROUBLESHOOTING
The user can solve some of these problems
himself, but for others specific technical
knowledge or skill is required, and so they
must only be carried out by qualified staff with
recognised experience acquired in the specific
sector of operation.
Causes
Electrical connection not
made correctly.
Safety thermostat tripped.
Switch faulty.
Air filter dirty or obstructed.
Air intake fan malfunction.
Electrical component overtem-
perature.
- 12 -
- 12 -
Remedies
Check the connection of the
electrical wires.
Important
Contact the after-sales service.
Wait until the operation is
automatically restored.
Replace the switch.
Important
Contact the after-sales service.
Clean the air filter.
Replace fan.
Important
Contact the after-sales service.
Wait until the indicator light
turns off automatically.
ENGLISH
ENGLISH