CLEANING THE PASTA BASKET
To carry out this operation, proceed as follows.
1 - Spread a suitable degreaser on the pasta bas-
ket and leave it to act for a few minutes.
2 - Rinse with drinking water.
GREASING THE DRAIN TAP
To carry out this operation, proceed as follows.
1 - Turn on the drain tap (A) to empty the pan, and
leave it open,
2 - Undo the screw (B) by a few turns.
3 - Pull off the cone (C)
4 - Check the seals for wear and replace them if
necessary (VITON O-RING ref. GB6212).
5 - Clean the cone (C) and its seat.
6 - Coat the cone (C) with grease, fit it in its seat
and turn it a few times.
N.B.: use food-approved grease (KLUBER PARAL-
IQ GTE 703W0), supplied with the appliance.
7 - Pull off the cone (C) to remove the excess
grease.
8 - Replace the cone (C) and tighten the screw (B).
TROUBLESHOOTING
The appliance has been tested before being put
into service. The information provided below is in-
tended to assist in the identification and correction
of any anomalies and malfunctions which might oc-
cur during use. The user can solve some of these
problems himself, but for others specific technical
knowledge or skill is required, and so they must
only be carried out by qualified staff with recognised
Fault
The heating elements do not come on.
The pressure gauge has detected an
abnormal pressure (>0.5 bar) inside the
jacket.
The safety thermostat is tripped too
often.
3 - Apply a specific product or a water and vinegar
4 - Rinse and dry the pasta basket.
FAULT
experience acquired in the specific sector of opera-
tion.
For all requirements contact the agents or
the headquarters of Angelo Po which can
be found in the contacts section of the web-
site http://www.angelopo.com.
Causes
Electrical connection not made correctly.
Safety thermostat tripped.
Switch faulty.
Pressure control valve fouled or damaged.
The water level in the jacket is not correct.
- 11 -
solution to the pasta basket to remove the de-
tergent residues.
C
B
C
Important
Check the connection of the
electrical wires.
Carry out the appliance reset (see
Replace the switch.
Clean the pressure control valve and call
the after-sales service if necessary.
Restore the water level in the jacket; if
necessary call the after-sales service.
A
IDM-39603602600.tif
6
Remedies
page 15).
English
IT
GB
DE
FR