Herunterladen Inhalt Inhalt Diese Seite drucken

Adjustment - Tractel tirak L 500 P Serie Original-Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für tirak L 500 P Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lubricate the lubrication nipple with 3–5 pumps (approx. 5 cm
Let the hoist run for approximately two seconds in the UPWARD and DOWNWARD directions.
Lubricate the lubrication nipple with 3–5 pumps (approx. 5 cm
8.5

Adjustment

8.5.1 Check the adjustment of the mechanical load limiting device
Risk of being injured by falling objects!
Might result in severe injuries or even death!
The load limiting device may only be implemented by personnel trained and certified by Tractel.
Observe the details in this instruction manual.
Always abide by the details given in the order specifications for special versions.
The load limiting device has been set up to activate at a specific overload.
The maximum overload that has to be set up can be found in the applicable directives and standards (see 3.4).
The system manufacturer is responsible for determining and setting up the application dependent maximum overload.
The hoist's load limiting device has been set up in the factory to activate with a maximum permitted overload of 125% of the working
load limit.
Hoists fitted with mechanical load limiting devices cannot normally be set up to activate with an overload that is less than 90% of the
hoist's working load limit.
The maximum overload must be lifted in order to set the load limiting device.
Overload = working load limit + 25 %
Model series X 300 P to X 1030 P, L 500 P
Illustration 29
Load the load lifting equipment with the calculated overload.
Raise the load.
The load limiting device must react and stop the UP travel of the hoist within the first 10 cm.
G1035.4 – 01/2019
).
3
).
3
DANGER!
Installation and operating manual
EN-53

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis