Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Technical Data; Accessories; Declaration Of Conformity - Emerson AVENTICS ITS Serie Betriebsanleitung

Pneumatische kolbenstangenzylinder (atex)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Dispose of the cylinder in accordance with your country's national regula-
u
tions.

11 Troubleshooting

Check the connections, operating voltage of the system part, and working
u
pressure if malfunctions occur.
If this is the cause of the malfunction, proceed as follows:
1. Ensure that the cylinder is not under pressure and disconnect the system part
from the supply voltage.
2. Remedy the malfunction.
3. Restart the system part and cylinder.
Additional help for malfunctions can be found in the following table:
Table 1: Troubleshooting
Malfunction
Possible cause
Loud impact or product vi-
Cushioning too weak or prod-
brates in end position
uct underdimensioned
Drop in performance during
Product defective
continuous operation
Product does not achieve out-
Supply lines too long
put, compressed air supply in-
Tubing diameter dimen-
sufficient
sioned too small
Possible throttle points in the
system

12 Technical Data

General data
Version
Temperature range
Mounting orientation
ATEX classification
Operating pressure
min./max
Permissible medium
Max. particle size
Oil content of compressed air
The medium dew point must be at least 15°C below the ambient and medium temperatures
and must not exceed 3°C. The oil content of compressed air must remain constant during
the service life. Use only the oils approved by AVENTICS.
Tubing length max.
Tubing diameter max.
Max. permissible operating frequency (dou-
ble stroke)
Max. permissible piston speed
Max. permissible circumferential speed on
the wearing surface
Further technical data for your configuration can be found in the online catalog.

13 Accessories

The accessories approved for your configuration can be found in the online cata-
log.

14 Declaration of conformity

See the end of these operating instructions.
AVENTICS™ | R412005817-BAL-001-AI | English
Remedy
Correct the cushioning (see
"Adjusting pneumatic cush-
ioning")
Replace product
Shorten supply lines
Select a larger tubing diame-
ter
Remove throttle points
(mounted fittings/elbow fit-
tings)
Double-acting cylinder
-20 °C ... +60°C
Any
(see "ATEX identification")
KPZ/MNI/CCI/CCL-IC/CSL-RD/RPC:
1... 10 bar
PRA/TRB/CCL-IS/ITS:
1.5 ... 10 bar
Compressed air prepared outside the explo-
sive area
50 µm
3
0 ... 5 mg/m
For cylinder Ø ≤ 25 mm: 5 m
For cylinder Ø ≥ 32 mm: 10 m
For cylinder Ø ≤ 25 mm: 6 mm
For cylinder Ø ≥ 32 mm: any
For cylinder Ø ≤ 25 mm: 0.33 Hz
For cylinder Ø ≥ 32 mm: 0.4 Hz
1 m/s
1 m/s
16

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis