Herunterladen Inhalt Inhalt Diese Seite drucken

Status Codes; Communication - Balluff BIS U-6026-034-104-06-ST35 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6026-034-1_4-06-ST35
Processor unit
8
Device function (continued)
8.1.4

Status codes

Status codes are only valid in combination with
the AF bit!
Sub-
Functional description
address
01
Job cannot be executed because there is no
hex
active data carrier in the active range of the
antenna.
02
Not possible to read the data carrier.
hex
03
Data carrier was removed from the range of
hex
the antenna during reading.
04
Cannot write to the data carrier.
hex
05
Data carrier was removed from the range of
hex
the antenna during writing.
07
No or invalid command identifier with set AV
hex
bit or the number of bytes is 00
09
Cable breakage at antenna or no antenna
hex
connected.
0E
There is more than 1 data carrier or more than
hex
1 selected data carrier in the active range of
the antenna and the executed command is
valid only for individual data carriers.
0F
First and second bit string not equal. The
hex
second bit string must be used.
43
Error when reading or writing parameters of
hex
the internal memory.
44
Arbitrary device behavior.
hex
46
Command outside the address range of the
hex
data carrier.
4E
No antenna activated.
hex
24
english
8.1.5
Communication between the controlling system and
processor unit is defined by a sequence protocol.
Communication between the controlling system and
processor unit is implemented using control bit in the
output and input buffer.
Basic sequence
1. The controller sends a command designator to the
processor unit in the output buffer with the AV bit set.
The AV bit tells the processor unit that a job is
beginning and the transmitted data is valid.
2. The processor unit accepts the job and confirms the
job by setting the AA bit in the input buffer.
3. If additional data needs to be exchanged for the job,
readiness for additional data exchange is indicated by
inverting the TI and TO toggle bits.
4. The processor unit has correctly executed the job and
sets the AE bit in the input buffer.
5. The controller has accepted all data. The AV bit in the
.
hex
output buffer is reset.
6. The processor unit resets all control bits set in the input
buffer during the job (AA bit, AE bit). The processor unit
is ready for the next job.