BIS U-6026-034-1_4-06-ST35
Processor unit
7
Setting the processor unit parameters (continued)
ETSI channels
The channel setting determines the channel assignment. If
multiple channels are activated, the device automatically
selects them by means of the frequency hopping method.
Factory setting:
Channel 4 switched on, channels
7...13 switched off
The ETSI channel selection is only available
when using the devices within the European
Union.
Transmitting power
The Gain and Loss parameters are defined in
the Antenna type and Cable type fields. These
values are used to determine the maximum
permissible radiated power.
The maximum permissible radiated power and
factory settings differ depending on the set
country profile. For information on the valid
regulations of the different countries, see
chapter Safety on page 6.
In the countries of the European Union, the
radiated power is specified in the form of ERP
(max. 2 watts
ERP
In the USA and Canada the radiated power is
specified in the form of an EIRP power (max.
4 watts
).
EIRP
See the "Basic UHF manual" for more
information on radiated powers.
20
english
).
Enabled:
Enables/disables antennas 1...4.
Factory setting:
Antenna 1 enabled, antennas 2...4
disabled.
Antenna type
Selection of the used antenna.
Factory setting:
BIS U-302-C1 or BIS U-302-C0
Port power
For selecting the power on the device (port power).
Factory setting:
22.5 dBm (176 mW) or 20.5 dBm
(112 mW)
Antenna power
Power at the antenna (EIRP or ERP).
Factory setting:
27 dBm (500 mW)
Cable type
Selection of the cable used.
Factory setting:
BIS U-500-EF-05