2.
Transport mode visualisation
When the key is turned to ON, the display (11, Fig. D)
automatically shows the transport/working mode page
(10, Fig. H) thus replacing the screen (1). The screen
(10) remains even after the engine has been turned on. It
shows the following parameters.
Engine speed
: 4-digit number (16, Fig. H) with the
ENG
following symbol
rpm
CAUTION!
If the engine speed sensor is faulty,
the switches on the display are not
illuminated. To repair the circuit and
replace the engine speed sensor, contact
a Nilfi sk Service Center.
Fuel level
: the fuel level is shown by the horizontal
bar indicator (15, Fig. H). The last bars indicate the
reserve, they fl ash when the level is low. The fuel level
instantaneous value in % (17, Fig. H) is shown too.
CAUTION!
If the fuel level is low, a continuous
warning buzzer signals the problem. The
warning buzzer can be reset by pressing
the button (12, Fig. D) on "SEL" for a few
seconds.
CAUTION!
If the level sensor is faulty, the display
shows warning messages according to
the type of fault (short or open circuit)
(for the alarm coding see the Alarm
Description paragraph). To repair the
circuit and replace the level sensor,
contact a Nilfi sk Service Center.
CAUTION!
If the level sensor is faulty, a continuous
warning buzzer signals the problem. The
warning buzzer can be reset by pressing
the button (12, Fig. D) on "SEL" for a few
seconds.
The symbol (18, Fig. H) indicates that the fuel level
indicator is activated.
8
USER MANUAL
(14).
33019741(2)2009-12 A
Engine coolant temperature
shown by the horizontal bar indicator (11, Fig. H). The
bars fl ashes in case of overheating. The temperature
instantaneous value (22, Fig. H) is shown too. The
symbol (21, Fig. H) indicates that the temperature
indicator is activated.
CAUTION!
If the coolant temperature is high, the
engine stops and a continuous warning
buzzer signals the problem. The warning
buzzer can be reset by pressing the
button (12, Fig. D) on "SEL" for a few
seconds.
CAUTION!
If the temperature sensor is faulty,
the display shows warning messages
according to the type of fault (short
or open circuit) (for the alarm coding
see the Alarm Description paragraph).
To repair the circuit and replace the
temperature sensor, contact a Nilfi sk
Service Center.
Dust control system tank water level
relevant indicator (19, Fig. H):
main tank and sub-tank are full
main tank and sub-tank are empty. In this
condition, the dust control system turns off after
about 10 seconds.
Machine operation mode
(20, Fig. H):
N, machine movement mode is not regular.
When pressing the drive pedal, the "N" symbol is
replaced by the symbol
WARNING!
When the drive pedal is pressed, if
the symbol
letter "N" still appears on the display, it
means that the parking brake is engaged
(release the lever) or that the pedal
sensors are faulty. In this case, contact a
Nilfi sk Service Center.