4. Installation

Prepare for the installation in the ZAPTEC Portal
Only ZAPTEC installation technicians/service partners can add installations in the ZAPTEC
Portal cloud solution. New installation technicians/service partners must contact ZAPTEC's
technical support via support@zaptec.com in order to have service authorisation added to
their user profile. They will then be able to add new installations.
Log on at https://portal.zaptec.com. If you wish to add a new ZAPTEC Portal installation,
go to Installations and fill in the form shown below:
Name: Give the installation a name.
Address: The address of the installation's physical location.
Category: Select the installation category from the drop-down list.
Network type: Choose the appropriate power grid for the location of the charging system.
Protection for charging system: The maximum current that the installation can use for
charging. This could be a digital budget or the value of the physical overload protection
or the power switch. If the charging station is located on a separate circuit, the maximum
current per phase must normally be set to the rating of the circuit breaker.
Add charging circuits to the installation
Once the installation has been set up, press the "Circuits" tab
Click on "Add circuit"
Enter the circuit designation stated in the fuse box
State the value [A] for overload protection
Charging stations that receive power from this charging circuit can charge up to the value of the charging circuit.
i
It can therefore be an advantage not to operate on full load.