Herunterladen Inhalt Inhalt Diese Seite drucken

ZAPTEC Pro Installationshandbuch Seite 12

Vorschau ausblenden Andere Handbücher für Pro:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

I
7
G
Sealing cones
Place the sealing cone over the cable entry in order to seal it
properly. First seal the unused cable entry using the sealing
cone supplied.
The sealing cone must be pulled down towards the junction
box and then pushed all the way down, so that the cone
ends up in the correct position as shown below. Visually
check that the seal has a good sealing surface.
9
Test the installation
To test the installation after the cover has been screwed on,
you must use the female connection. If you test directly on
the back plate, the connections will be damaged.
3
10
Protect the connections
Apply the adhesive sticker to protect the connections.
12
Good sealing surface
Poor sealing surface
or
H
4
8
Screw on the junction box cover
Attach strain reliefs to both cables and the sealing cone
before placing the cover on the junction box and screwing in
the four screws.
Use the correct sealing cone for the cable. Check
the cable dimension and select an appropriate
i
sealing cone. Small sealing cone – cable
dimension 10-16. Large sealing cone – cable
dimension 16-21.
Dept.
Technical reference
Do not insert measuring pins, wires or anything else
into the quick-release connector on the back plate.
i
Voltage tests should be performed directly on the
coupling screws or using a female coupling.
5
Created by
Fredrik Ostrem
07.1
Document type
Title
Bakplate ute innsta
6

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für ZAPTEC Pro

Inhaltsverzeichnis