Troubleshooting
Fault
Increased generation of noise and vi-
bration in the electrical drive system.
When switched on, the screen displays
a combination of E 208, E 210, and
E 138
For any error which is not listed, and for any error which cannot be corrected through the measures described above, contact Torqeedo Service or an authorised service part-
ner.
If the "Insulation fault" error message appears in the display, the insulation of the high voltage system is damaged. The electrical drive system remains in running order,
but it must be inspected immediately by Torqeedo Service. Because of the linked safety systems of the electrical drive system, two insulation faults must exist simultane-
ously for there to be a risk of injury. After warning of an insulation fault, avoid contact with metallic parts.
All manuals and user guides at all-guides.com
Checking/correction
Contact Torqeedo Service or an authorised service partner.
Check that the emergency kill switch is correctly seated, and push it on if necessary.