17. WARNING MESSAGES ON THE DISPLAY

REVERSE POLARITY
CONNECTION BREAK
SHORT ERR
INPUT VOL ERR
VOL SELECT ERR
BREAK DOWN
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOLTAGE
CELL LOW VOL
The polarity of the battery connections has been
switched.
The connection to the battery has been
disrupted, e.g. if the battery was disconnected
during the charging process.
A short circuit has been identified on the
charger output.
The input voltage (operating voltage) for the
charger is too low.
The voltage of a LiPo, LiIon, LiFe battery to be
charged has been incorrectly configured.
The charger has identified an internal problem.
Should this message be displayed permanently,
it is possible that the charger is faulty; have it
checked by a specialist workshop or qualified
technician.
During the charging process it was identified
that the battery is totally discharged.
Check if the battery voltage was set correctly for
charging.
The voltage in one of the cells of a lithium
battery (LiPo, LiIon, LiFe) is too low. This can
occur if a multi-cell battery was previously
charged without a balancer.