Herunterladen Inhalt Inhalt Diese Seite drucken

C) Discharging Batteries („Discharge") - VOLTCRAFT Ultimate 400 W Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

c) Discharging Batteries („DISCHARGE")
• After you have selected the „Pb" program in the main menu with the button „BATT TYPE/
STOP" and confirmed this with the button „START/ENTER", you can select the discharge
function using the button „INC" or „DEC":
Pb DISCHARGE
0.1A
The value on the left in the second line shows the discharge current, the value on the
right shows the voltage or number of cells of the battery (in this example, a 6-cell lead
battery, 6x 2.0 V = 12.0 V).
• If the values need to be changed, push the „START/ENTER" button. The discharging
current flashes. Change the discharging current using the keys „INC" and „DEC" and
confirm the value using the „START/ENTER" button.
• The voltage/cell number then begins to flash. Change this using the buttons „INC" and
„DEC". Observe that the voltage is only changed by the number of cells (e.g. one cell =
2.0 V, two cells = 4.0 V, etc.). Confirm the setting by pressing the „START/ENTER"
button.
For safety reasons, the charger sets the final discharge voltage automatically.
• To begin the discharge process, keep the „START/ENTER" button pressed for longer
(approx. 3 seconds).
• If the settings are wrong, or if the charger detects a problem, an audio signal is emitted
and the appropriate information is shown on the display.
You can stop the warning signal by pressing the „BATT TYPE/STOP" button. You then
return to the previous configuration menu.
• If you push the button „START/ENTER" during the discharge process, the discharge
current can be changed (see above).
• Once the discharge process is complete, an audio signal is emitted.
If you wish to terminate the discharging process beforehand, push the „BATT TYPE/
STOP" button.
80
12.0V(6P)

Werbung

Inhaltsverzeichnis
loading