Herunterladen Inhalt Inhalt Diese Seite drucken

Warning Messages In The Display - VOLTCRAFT Ultimate 1000 W Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

18. WARNING MESSAGES IN THE DISPLAY

REVERSE POLARITY
CONNECTION BREAK
Connection error
Check Main Port
BALANCE CONNECT
ERROR
Input too low
Min.Input: 11.0V
DC too hi
Cell error
High voltage
Cell error
Voltage invalid
Cell number
Incorrect
Int.temp.too hi
Ext.temp.too hi
Over charge
Capacity Limit
Over TIME LIMIT
Battery was full
The polarity of the battery connections is reversed.
The connection to the battery is interrupted, e.g. if the battery was unplugged
during charging.
The battery is connected with reverse polarity.
The balancer of the battery is connected incorrectly or with reversed polarity.
The charger's input voltage (operating voltage) is too low (<11.0 V).
The charger's input voltage (operating voltage) is too high (>30.0 V).
The voltage of one of the cells of the connected lithium battery is too high.
The voltage of one of the cells of the connected lithium battery cannot be
read.
The number of cells set is wrong.
The charger's temperature is too high. If necessary, check the two fans.
The battery temperature measured via the external sensor is too high.
The set capacity limit (see Chapter 16) has been exceeded.
The set time limit for the charging process (see Chapter 16) has been
exceeded.
The connected battery is full. You may need to check the setting of the cell
count.
91

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis