BATTERY VOLTAGE
CELL HIGH VOL
BATTERY
CELL CONNECT
TEMP OVER ERR
CONTROL FAILURE
92
VOLTAGE
The voltage in one of the cells of a lithium
battery (LiPo, LiIon, LiFe) is too high. This can
occur if a multi-cell battery was previously
charged without a balancer.
The balancer cable was connected incorrectly or
does not match the pin assignment of the
charger.
Overtemperature was detected in the the
charger (e.g. when discharging rechargeable
batteries). Leave the charger and the battery to
cool down.
The charger has identified an internal problem.
Should this message be displayed permanently,
it is possible that the charger is faulty; have it
checked by a specialist workshop or qualified
technician.