Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT Ultimate 400 W Bedienungsanleitung Seite 75

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

If the current value flashes, you can switch between manual („Man") and automatic
(„Aut") mode by simultaneously pressing the buttons „INC" and „DEC".
In manual mode („Man"), the batteries are charged with the current you have set.
In automatic mode („Aut"), the charger calculates the charging current automatically;
all you do is set the top limit for the charging current. Shorter charging times can be
achieved depending on the battery and its internal resistance.
• Change the charging current (or in automatic mode the top limit for the charging current)
using the buttons „INC" and „DEC", confirm the value using the „START/ENTER" button.
The number of cells is automatically identified!
• To begin the charging process, keep the „START/ENTER" button pressed for longer
(approx. 3 seconds).
• If the charger detects an error (e.g. no battery connected), a warning signal is emitted
and a corresponding info appears on the display.
You can stop the warning signal by pressing the „BATT TYPE/STOP" button. You then
return to the previous configuration menu.
• If the battery is detected correctly, the following display appears, for example:
Battery type
NiMH 2.0A
CHG 043:20 01253
Current charging duration
• Once the charging process is complete, an audio signal is emitted.
If you wish to terminate the charging process beforehand, push the „BATT TYPE/
STOP" button.
Charge Current Battery Voltage
7.42V
Charged capacity in mAh
75

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis