18. WARNING MESSAGES ON THE DISPLAY

Warning message on the display
"INT. TEMP TOO HIGH"
"EXT. TEMP TOO HIGH"
"DC IN TOO LOW"
"DC IN TOO HIGH"
"OVER TIME LIMIT"
"OVER CAPACITY LIMIT"
"REVERSE POLARITY"
"CONNECTION BREAK"
"CELL NUMBER ERROR"
"BALANCE CONNECTOR ERROR"
"NO BATTERY"
"CONNECTION ERROR"
"BATTERY WAS FULL"
100
Description
The temperature of the charger is too high. Check
the fans if required.
The temperature measured at the rechargeable
battery via the external sensor is too high.
The input voltage (operating voltage) for the charger
is too low (< 11.0 V).
The input voltage (operating voltage) for the charger
is too high (> 18.0 V).
The set time limit for charging (see chapter 15) has
been exceeded.
The set capacity limit (see chapter 15) has been
exceeded.
The rechargeable battery was connected with
reversed polarity.
The connection to the battery has been disrupted,
e.g. if the battery has been disconnected during the
charging process.
The set cell number is wrong.
The balancer connection of the rechargeable
battery has been connected incorrectly or with
reversed polarity.
No rechargeable battery is connected or the
rechargeable battery has not been recognised (e.g.
defective/deep discharged).
The rechargeable battery has been connected in-
correctly or the charger recognises doubtful values.
The connected rechargeable battery is fully
charged. If required, check the cell number settings.