Parameters

MMA welding

The HCU (HotStart current) function and available setting range are described in the sec-
tion headed "MMA welding".
HCU
HotStart current
Unit
Setting range
Factory setting
Hti
Hot-current time
Unit
Setting range
Factory setting
FAC
Factory - reset power source
Press and hold the Setup / Store button (7) for 2 s to reset the device to its original (i.e.
factory) settings. If the display reads "PrG", then the power source has been reset
IMPORTANT! When the power source is reset, all personal settings in the Level 1 Setup
menu are lost.
The functions in the second level of the Setup menu (2nd) are also deleted.
2nd
Second level of the Setup menu (see section "Setup menu: level 2")

TIG welding

2nd
Second level of the Setup menu (see section "Setup menu: level 2")
92
m/min
0 - 100%
50%
s
0 - 2.0 s
0.5 s