Herunterladen Inhalt Inhalt Diese Seite drucken

Before Commissioning; Safety; Proper Use; Setup Regulations - Fronius TransPocket 4000 CEL Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TransPocket 4000 CEL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Before commissioning

Safety

Danger from incorrect operation.
This can result in serious injury and damage to property.
► Do not use the functions described here until you have read and completely under-
► Do not use the functions described here until you have fully read and understood all of

Proper use

The power source is intended solely for MMA and TIG welding and arc air gouging.
Any use above and beyond this purpose is deemed improper. The manufacturer shall not
be liable for any damage resulting from such use.
Proper use also includes:
-
-

Setup regulations

The power source is tested to degree of protection IP 23, meaning:
-
-
The power source can be set up and operated outdoors in accordance with degree of pro-
tection IP 23. However, the built-in electrical components must be protected against direct
wetting.
Danger from machines falling or toppling over.
This can result in severe personal injury and damage to property.
► Place devices on a solid, level surface in such a way that they remain stable.
The venting duct is a very important safety device. When choosing the device location, en-
sure that the cooling air can enter and exit unhindered through the air ducts on the front
and back of the device. Any electroconductive metallic dust (e.g. from grinding work) must
not be allowed to get sucked into the device.

Mains connection

The devices are designed for the mains voltage specified on the rating plate. The fuse pro-
tection required for the mains lead can be found in the "Technical data" section. If there is
no mains cable or mains plug on your device, fit one that conforms to national standards.
An inadequately dimensioned electrical installation can cause serious damage.
The mains lead and its fuse must be dimensioned to suit the local power supply. The tech-
nical data shown on the rating plate applies.
80
WARNING!
stood these Operating Instructions.
the Operating Instructions for the system components, in particular the safety rules.
Following all the instructions contained in the Operating Instructions
Performing all stipulated inspection and servicing work
Protection against penetration by solid foreign bodies greater than 12 mm in diameter
Protection against spraywater at any angle up to 60° to the vertical
WARNING!