MMA welding

Safety

Danger from incorrect operation.
This can result in serious injury and damage to property.
► Do not use the functions described here until you have fully read and understood the
► These Operating Instructions
► All the Operating Instructions for the system components, especially the safety rules
Risk of electric shock.
An electric shock can be fatal. If the device is plugged into the mains during installation,
there is a high risk of serious injury and damage to property.
► Only carry out work on the device if the mains switch is in the "O" position.
► Only carry out work on the charger when it has been disconnected from the mains sup-

Preparation

1
2
3
4
5
6
MMA welding
Risk of electric shock.
This can result in serious injury and damage to property.
► As soon as the mains switch is in the "I" position, the rod electrode in the electrode
1
2
The welding voltage is applied to the welding sockets with a 3-second time lag.
IMPORTANT! Parameters which can be adjusted on the TR 2000 / 3000 / 4000 remote
control cannot be altered on the power source. These parameters can only be altered on
the TR 2000 / 3000 / 4000 remote control.
84
WARNING!
following documents:
WARNING!
ply.
Move the mains switch to the "O" position
Disconnect the mains plug
Plug the grounding cable into the current socket, depending on the type of electrode,
and fasten it in place
Use the other end of the grounding cable to establish a connection to the workpiece
Plug the welding power-lead into the current socket, depending on the type of elec-
trode, and fasten it in place by turning it clockwise
Plug in the mains plug
WARNING!
holder is live. Make sure that the rod electrode does not touch any persons or electri-
cally conductive or earthed parts (e.g. the housing, etc.)
Move the mains switch (8) to the "I" position (all the indicators on the control panel will
briefly light up)
Select one of the following processes using the Process button (3):
MMA welding
MMA welding with Cel electrode
Special processes