Welding current at
Standardised working voltage
Maximum working voltage
Open circuit voltage (pulsed)
Degree of protection
Mark of conformity
Type of cooling
Insulation class
Dimensions l x w x h
Weight
1)
2)
TP 5000 CEL
Mains voltage
Mains voltage tolerance
Mains fuse protection
Mains connection
Primary continuous power
Cos phi
Efficiency
Welding current range
Welding current at
Standardised working voltage
Maximum working voltage
Open circuit voltage (pulsed)
Degree of protection
Mark of conformity
Type of cooling
Insulation class
Dimensions l x w x h
Weight
1)
2)
10 min / 40°C
10 min / 40°C
10 min / 40 °C
Connected to public grids with 230 / 400 V and 50 Hz
D.C. = Duty cycle
1)
100% D.C.
10 min / 40°C
10 min / 40°C
10 min / 40 °C
Connected to public grids with 230 / 400 V and 50 Hz
D.C. = Duty cycle
40% D.C.
60% D.C.
100% D.C.
MMA
TIG
MMA
Peak value
Average value
2)
MMA
TIG
40% D.C.
60% D.C.
100% D.C.
MMA
TIG
MMA
Peak value
Average value
2)
380 A
2)
360 A
2)
320 A
20.4 - 35.2 V
14.5 - 33 V
53 V (380A)
80 V (10 A)
95 V
60 V
IP 23
S, CE
AF
F
625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
40 kg
88.2 lbs
3 x 400 V
+/- 15%
35 A slow-blow
Restrictions possible
16.3 kVA
0.99
90%
10 - 480 A
10 - 480 A
2)
480 A
2)
415 A
2)
360 A
20.4 - 39.2 V
14.5 - 38 V
48 V (480A)
80 V (10 A)
95 V
60 V
IP 23
S, CE
AF
F
625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
37 kg
81.6 lbs
103