Herunterladen Inhalt Inhalt Diese Seite drucken

Checking Measured Values - Bosch EPS 708 Montageanleitung

Common rail prüfstand
Vorschau ausblenden Andere Handbücher für EPS 708:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
48 | EPS 708 | Calibrating high-pressure rail
7.10

Checking measured values

1. Call up the "Meas. funcs" selection menu with <F7>.
2. Select the "Automatic on/off" menu item and
activate the automatic mode function with <F12>.
 The automatic mode symbol flashes in the
operating status display.
 The specified values are set and the waiting time
commences. On completion of the waiting time,
the software switches automatically to the next
test step.
3. In the event of the message "
No further test step! Results with F12
>>.
" call up the protocol with <F12>.
Fig. 28:
Excerpt from the test protocol
1 Measured value: External pressure value
2 Measured value: Test bench press.val. upst.of filter
3 Measured value: Test bench pressure value
4. At all verification points, compare the measured
values Test bench pressure value and Test bench
press.val. upst.of filter to External pressure value
(refer to Fig. 28). The difference in pressure must
not exceed 0,5 MPa.
Calibration must be repeated if the pressure
difference is > 0,5 MPa.
|
1 689 978 559
2017-12-08
System stop!
7.11
End of calibration
1. Exit from the "Result printout" dialog window
with <Esc>.
2. In the "Injection component test main menu" start
screen select <F7>.
 A password request appears.
3. Enter the password in the input line:
4. Confirm the entry with <F12>.
5. Select the menu item Calibration >> Rail pressure
sensor.
6. Select <F6> "Calib. check".
7. Continue with <F12>.
8. Exit from the menu with <Esc>.
 The software performs re-initialization of the de-
vices.
9. Remove the USB connecting cable of the pressure
sensor from the PC.
10. Remove the pressure sensor from the high-pressure
rail.
11. Use a dummy plug to seal the connection for the CRI
846 distributor rail at the high-pressure rail.
12. Remove the common rail pump.
"
Pressure sensor calibration is over.
1958
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis