40 | EPS 708 | Commissioning
4.11.2
Filling with cooling water
i
The following description only applies to the
EPS 708 with cold water unit.
!
Only fill the cold water unit with clean, filtered
water. Make sure the hose is clean before filling.
!
Never put any additives in the cooling circuit as
these would affect the cooling output.
1. Open both valves (Pos. 1 and Pos. 2) at the cold
water unit. To do so, set the valves parallel to the
direction of flow.
1
Fig. 19:
Valves at cold water unit
|
1 689 978 559
2017-12-08
2. Remove the sealing plug at the inlet cock
(refer to Fig. 20, Pos. 1) of the cold water unit.
i
The sealing plug is needed again later.
3. Connect the inlet cock (Pos. 1) via a hose (Pos. 2)
to the water cock of the water mains.
Fig. 20:
Cold water unit connection
4. On the back of the EPS 708, route the drain hose
(refer to Fig. 21, Pos. 3) into a plastic vessel or the
2
like (Pos. 2).
3
Fig. 21:
Bleeding