7. Diagnostics for minor faults

The generating set...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
Check that:
The pre-starting checks
have been carried out and the oil cut-
out warning light is off.
YES
The starting procedure has been
performed, the fuel tank's vent tab and
fuel tap are open.
YES
The fuel tank is at least half full/the
generating set has been switched off for
less than 10 minutes.
YES
The spark plug is correctly
connected/does not need replacing.
YES
The devices to be used have not been
connected prior to starting.
YES
The oil level is correct, the oil cut-out
warning light is off.
YES
The fuel level is correct.
YES
Maintenance has been correctly
performed on the generating set
components.
YES
Have the generating set checked by a
professional.
Tripped circuit breaker(s).
YES
The connected devices and their power
cords are not faulty.
YES
Have the generating set checked by a
professional.
Solutions to be applied:
Perform the checks.
NO
Follow the starting instructions carefully,
open the fuel tank's vent tab and fuel tap if
NO
necessary.
Use the fuel tank's pressurising pump in
accordance with the instructions.
NO
Connect, clean or replace the spark plug.
NO
Disconnect the devices then try to restart
NO
the generating set.
Top up with oil.
NO
Fill up with fuel or use the fuel tank's
pressurising pump in accordance with the
NO
instructions.
Perform maintenance on the generating set
in accordance with the recommendations
NO
Check the capacity of the generating set
and press the circuit breakers.
NO
Try with another device and another power
NO
19
cord.