• Always use caution when you take X-rays with the Fowler backrest in the upright position or when you use a lateral
cassette.
• Always use extra caution when you use a mattress thicker than 2.5 in. or a mattress overlay with P P r r i i m m e e X X option.
• Always follow the Positioning the lateral X-ray cassette holder - Prime X option instructions to insert the X-ray cassette.
To position the lateral X-ray cassette holder:
1. Apply the brakes. Push on the product to make sure that the brakes are working.
2. Press down on the yellow release button (A) to open the lateral cassette holder (Figure 28).
3. Slide the flat base (B) between the mattress and the patient platform.
4. Position the lateral cassette holder in the desired location.
5. Place the X-ray cassette in the cassette canal (C).
6. Pull up on the cassette hook (D) to adjust the height of the arm to fit over the X-ray cassette to hold the cassette in
place.
7. Reverse steps to remove the cassette and stow the lateral cassette holder.
I I n n s s e e r r t t i i n n g g o o r r r r e e m m o o v v i i n n g g X X - - r r a a y y c c a a s s s s e e t t t t e e s s - - P P r r i i m m e e X X o o p p t t i i o o n n
W W A A R R N N I I N N G G
• Always refer to local, state, and federal guidelines in addition to facility protocols for safety before you use P P r r i i m m e e X X
option with radiation generating devices. Radiation generating devices may produce residual, stray, or scattered
radiation.
• Always use caution when you take X-rays with the Fowler backrest in the upright position or when you use a lateral
cassette.
P P r r i i m m e e X X option provides both an articulating radiographic support surface and a platform below the patient support surface
for X-ray cassette placement. Working with medical X-ray systems, the radiographic support surface allows the capture of
clinical X-rays (AP full body, optional full body lateral, and optional upright chest) while the patient is on the product. You
can insert cassettes from the head end, foot end, and either side of the product.
To insert an X-ray cassette:
1. Center the patient on the product with the position indicator labels located on all sides of the product (Figure 29).
2. Insert an X-ray cassette below the patient surface. Use the cassette guides to assist in positioning the X-ray cassette.
1105-409-005 Rev E.1