To raise the litter, press down on the pump pedal (A) until you achieve the desired height ( Prime base controls (page 16)).
L L o o w w e e r r i i n n g g t t h h e e n n o o n n - - e e l l e e c c t t r r i i c c l l i i t t t t e e r r
W W A A R R N N I I N N G G
• Always position the patient in the center of the product.
• Always put the product in the lowest position with the siderails up and latched when you leave a patient unattended. Do
not leave the product at a higher height.
• Always remove any devices that may be in the way before you raise or lower the litter.
• Do not sit on the end of the product. The product may tip.
C C A A U U T T I I O O N N - - Do not use the hydraulics on the base to raise the product with a patient lift under the product.
To lower the entire litter, press down on the center of the uni-lower pedal (C) ( Prime base controls (page 16)).
To lower the head end of the litter, press down on the pedal (B) or on side of the uni-lower pedal (C) closest to the head end
of the product.
To lower the foot end of the litter, press down on the pedal (D) or press down on the side of the uni-lower pedal (C) closest
to the foot end of the product.
R R a a i i s s i i n n g g t t h h e e e e l l e e c c t t r r i i c c l l i i t t t t e e r r o o p p t t i i o o n n
W W A A R R N N I I N N G G
• Always position the patient in the center of the product.
• Always put the product in the lowest position with the siderails up and latched when you leave a patient unattended. Do
not leave the product at a higher height.
• Always remove any devices that may be in the way before you raise or lower the litter.
• Do not sit on the end of the product. The product may tip.
C C A A U U T T I I O O N N - - Do not use the hydraulics on the base to raise the product with a patient lift under the product.
To raise the electric litter, press down on the pump pedal (A) until you achieve the desired height ( Prime base controls
(page 16)).
L L o o w w e e r r i i n n g g t t h h e e e e l l e e c c t t r r i i c c l l i i t t t t e e r r o o p p t t i i o o n n
W W A A R R N N I I N N G G
• Always position the patient in the center of the product.
• Always put the product in the lowest position with the siderails up and latched when you leave a patient unattended. Do
not leave the product at a higher height.
• Always remove any devices that may be in the way before you raise or lower the litter.
• Do not sit on the end of the product. The product may tip.
C C A A U U T T I I O O N N - - Do not use the hydraulics on the base to raise the product with a patient lift under the product.
To lower the entire electric litter, press on the center of the uni-lower pedal (C) ( Prime base controls (page 16)).
To lower the head end of the litter, press down on the pedal (B) or push down on the side of the uni-lower pedal (C) closest
to the head end of the product.
1105-409-005 Rev E.1
17
EN