Herunterladen Inhalt Inhalt Diese Seite drucken

Residual Risks; Assembly; Risk Of Injury - Parkside PNTS 250 C2 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PNTS 250 C2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding.
• Never keep the fingers between the
grinding disc and spark protection or in
close proximity to the protective hoods.
There is a risk of crushing.
• The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and hold
the workpiece firmly in order to avoid
slipping which could cause your hands
to come into contact with the grinding
disc.
• The workpiece gets hot during grind-
ing. Do not touch the machined area,
allow it to cool down. There is a risk of
burning. Do not use coolants or the like.
• If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
• Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
• Only operate the equipment in an up-
right, standing position and ensure you
have secure footing.

Residual risks

Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage, if suitable respiratory
protection is not worn.
b) Hearing damage, if suitable ear protec-
tion is not worn.
c) Damages to health due to
- touching the area of the grinding tool
which was not covered;
- the ejection of pieces from workpiece
or damaged grinding discs.
d) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we rec-
ommend that persons with medical
implants consult their doctor and
the manufacturer of their medical
implant before operating the ma-
chine.

Assembly

Caution!

Risk of injury!

- Ensure that you have sufficient space
in which to work, and that you do
not endanger other people.
- Always fasten the device on to the
work surface with screws featuring
the sufficient length and thickness in
order to maintain control of the de-
vice.
- All covers and protective devices
must be assembled properly before
commissioning.
- Disconnect the mains plug before
changing the setting on the device.
GB
NI
IE
11

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis